HPIC-D-HV

  • HV — High Volume
  • All the great features of HPIC-D
  • 20 GPM @ 40 PSI fill rate
  • Auto switchover to high pressure
  • Standard ¾” NPT x 15′ output hose

The WIDDER HPIC-HV High Volume Hydrostatic Test Unit is a portable, air driven, hydrostatic test system. This test unit features a rugged powder coated steel body construction, and screen printed informational graphics for long-life. This unit also features our standard, stainless steel, 140 Mesh (100 Micron) water inlet filter, as well as full air filtration and lubrication. The HPIC-HV High Volume Hydrostatic Test Unit is built for easy, reliable service by utilizing access panels and flare seat seals. This unit is ergonomically designed featuring a tilted front for convenience of use, as well as a t-handle and large 10” wheels for easy maneuvering. The standard Isolation Valve allows complete isolation from the pump check valve when higher system integrity is required.

The WIDDER HPIC-HV High Volume Hydrostatic Test Unit comes standard as digital unit but can also be optioned as an analogue only unit. The digital version uses state-of-the-art digital technology to test with higher accuracy. All digital gage options are certified Intrinsically Safe and at least 0.25% full scale accurate. WIDDER also offers an optional digital logging gauge. This gauge is capable of storing over 21,000 individual strings of data, including date, time, temperature and pressure. This data can be downloaded from the gauge with convenient software and converted to Excel. With the additional 4” liquid filled analog gauge, these systems can be cross-checked in the field for accuracy while in use.

The WIDDER HPIC-HV High Volume Test Unit is unique to the industry. This C style pump uses identical technology to our standard HPIC workhorse, but adds an innovative low-pressure bypass system. This design offers fast fill rates up to 20 GPM with instant, automatic, switchover to high pressure testing after filling is complete. The HV series of pumps eliminates the need for costly 2-stage pumps or difficult multiple pump operations and hose changes.

*The HPIC-HV comes standard in 10,000 PSI, however other pressure options are available.

Lubrication: for optimal longevity and performance, use WIDDER Air Tool Lubricant.

Maintenance: contact a factory authorized service representative for maintenance; only use genuine WIDDER replacement parts.

Read the operating manual and follow safety procedures at all times!

Weight: 105 lbs.
Maximum Output Pressure: 9,700 PSI @ 100 PSI air input (standard)
Maximum Water Flow Rate: 20 GPM (with 3/4″ ID, 40 PSI inlet hose)
Water Inlet/Outlet: 3/4 NPT Female
Maximum Air Input Pressure: 100 PSI
Air Consumption: 56 CFM @ 100 PSI (no load)
Air Inlet: Universal Hose Coupling